Simultaneous quantification of ibogaine and noribogaine in human plasma and whole blood by liquid chromatography with electrospray ionization mass spectrometric detection
Mechanisms In vitro moderate
⚠ Contains fatality data
AI-extracted · unverified · confirm at source
First validated LC-ESI-MS method for ibogaine/noribogaine in plasma (LLOQ 0.89/1 µg/L) and whole blood (LLOQ 1.78/2 µg/kg). Fatal poisoning case: blood levels 10.8 µg/g ibogaine, 20.8 µg/g noribogaine (10–20× therapeutic).